Raisecom Technology Co., Ltd
19
7. Appendix Introduction of Cable Making
A.1 E1 interface
z 75ohm adopting DB37 coax adapter:
Suggest using SYV 75-2-2 coax cable, the distance less than 200 meter.
z 120ohm DB37 male connector is defined as following:
DB37 pin
definition
1
st
2
nd
3
rd
4
th
OUT 3、4 7、8 11、12 15、16
IN 21、22 25、26 29、30 33、34
Others hang up. Twisted pairs can be jointing on DB37 female connector.
A.2 Cable of Ethernet
Use RJ45 Cat. 5 twisted-pair cable to connect the equipment. The cable shall not be longer
than 100 meters.
Both straight-through and crossover cables will work.
RJ45 line order as following:
Pin
number
1 2 3 4 5 6 7 8
Definition TX+ TX- RX+
Not Used Not Used
RX-
Not Used
Not Used
A.3 RS232 cable of data channel
Adopting RJ45 connector, definition of pins as following:
3 ——RXD 232 signal input
6 ——TXD 232 signal output
4, 5 ——GND
others —— hang up (unassigned)
RS232 (RJ45) connection to console of computer (DB9 female connector) line order:
RJ45 DB9F
3 ←— 3
Pin 1 Pin 8